myson apollo 30/50b?

hi i wondered if any one can help after having to fit a new thermo coupling to my myson apollo 30/50b it made a banging noise like air trapped in the pipes? and it has then blown the new thermo coupling why ? thats 2 T/Cs in 2 months?

marks
January 2011
I a similar problem, a small clunk, then a rush of bubbles surging thru' the system and finally a massive banging noise, like someone hitting a radiator with a hammer. Pump overrun stat, goes in the back towards the bottom on the right onto a pipe coming off the heat exchanger. You need to take off the upper, outer cowelling, then the inner cover to get at it, costs about £15.00. Just unscrew old overrun stat and replace, only a few wires. Make a note of existing set-up or take a photo for reference if you really need to but it is very, very simple and obvious once you get the covers off.

DainO
November 2012
thanks for your quick reply will look into both as they are both getting on i years

marks
January 2011
you can't blow a t/c most likely cause is pump or divertor/zone valves faulty causing overheat stat to trip this disables the t/couple once they have tripped they can become tempremental

brian
January 2011

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Help Fit Thermo

Mend Heating, Home Heating Systems
Mend repair fix Myson home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Mend repair fix Myson home heating systems