Recent: How to recoil the starter spring - Champion R484TR?

Mend Cannon Convector Heaters

Mend Heating, Convector Heaters
Find out how to mend it for free.

Ask Question
Mend Heating, Convector Heaters
Click here to mend Cannon convector heaters

Mend > Convector Heaters

Mend Heating, Convector Heaters

i have a cannon caress gas fire. the fire switches itself off?

The fire has low med and high settings. When left on low for a while the pilot goes out. I wondered if the pilot was adjustable as it seems weak on low setting.

phil dobson
October 2008
I used the manual here: http://www.rinnaisales.co.nz/tradesmart/rinnai2/pdfs/installations/190.pdf

I disassembled the pilot burner and injector.

I removed the thumscrew and the pilot shield and then unscrewed the two screws which held on the pilot shield mounting bracket.

I then removed the retaining assembly screw.

I then lifted off the pilot burner and blew that out, and then unscrewed the injector on which the pilot burner stood (using TWO spanners so as not to damage the pipe).

The injector inside was almost blocked with a sort of black charcoal membrane, so I cleaned that out with a cotton bud and put it all back together.

Now my pilot light covers the thermocouple when properly lit!

Sam
December 2009
I am having same problem, had new thermocouple fitted last wk by corgi registered gas man and the same is still happening, had to call him back in.

john young
February 2009
replace the thermocoupple located behind the heat sheild on the front l/h side.

rob
January 2009

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Fire Low Settings

Mend Heating, Convector Heaters
Click here to mend Cannon convector heaters

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Convector Heaters
Click here to mend Cannon convector heaters