3 hours ago: Clear E1 error code on smeg dishwasher with no water or leak?

Mend Ferroli Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Free repair help for Ferroli home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

Ferroli Optima 901 -Intermittent Hot water problem?

Hi I have a Ferroli Optima 901 combi boiler and have recently been experiencing intermittent problems with no hot water. Shortly after this started I lost all pressure in the CH side which turned out to be a faulty pressure relief valve. This was replaced and the system repressurised to 1.5 bar (while cold).

I noticed that this pressure rises to 2.25bar when the CH is on, i assume that this is correct due to the expansion caused by the increased temperature.

The only thing I can think of is that the problem seems to happen when the CH is not on (or at least thats when ive noticed it) thus the CH system pressure is at its lowest. I know the Boiler shuts down at 0.5 bar, is it possible for this sensor/valve (or whatever) to be faulty? Or any other ideas?

The guy that replaced the pressure releif valve (wish i had changed it myself now!)mentioned something about an expansion vessel!? Whats one of those? Sorry for the ignorance, trying to understand whats going on and hopefully fix it before summer - if it is an issue thats caused by the heating being off!

Thanks Chris

Chris
March 2006
Hi thanks Paul, just one question, how do I locate the diverter valve and the relevant micro switches? Thanks

Chris
March 2006
most likely to be diverter valve. this has a diaphragm in it that over time stretches so not making the micro switches.its not a hard repair i suggest turning tap on and manually making switch seeif water runs hot .if it does then its diverter. sometimes called shunt valve.make sure water is off and system empty.also electric off.rest basic dont try diaphragm replacement not always succesful and could be catastrophic as connected to cold mains

paul
March 2006

Automatic Answer

We may have found other answers which could help you.

Click here for Ferroli Optima Hot Water

Mend Heating, Home Heating Systems
Free repair help for Ferroli home heating systems

Other models...

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Free repair help for Ferroli home heating systems