Recent: Gaggenau fridge alarm problem?

Mend Home Heating Systems

Heating, Home Heating Systems
howtomendit.com find out how to mend just about anything.
Categories

Mend Main

Free repair help

We have 880 questions about mending 'main' in category Heating, Home Heating Systems

How to mend Main

Mend fault light control

potterton main combi 30 he fault?

i have a red light up on control panel but it is the 60 degrees button lite up and not the normal ones below, ... [Read more]
Mend pilot main burner

worcester 230 rsf?

pilot lights but main burner does not come on
Mend pressure boiler years

Pressure Drop?

I have a Grant Combi 90 Mk II boiler and approx 5 years ago had a tiger loop (GOK GS2000) fitted internally ne... [Read more]
Mend glow worm saver pilot

glow worm fuel saver f,pilot lights but main burners wont?

my old glow worm fuel saver f lights up on the pilot no problem,but the main burners will not ignite.Was worki... [Read more]
Mend if gas switched
1

how can I tell if the gas valve is being switched?

We have an old Potterton Netaheat 5/10 boiler, everything seems to be working, except gas to the main burner! ... [Read more]
Mend Heating, Home Heating Systems

Yellow liquid has ben leaking from my Worchester Boiler, any suggestion how?

Yellow liquid has leaked from the connection between the pump and the main body of the boiler, any suggestions... [Read more]
Mend potterton netaheat electronic boiler
2

how do i fix my potterton netaheat electronic boiler?

the main burner won't ignite
Mend main combi boiler

Main combi - Hot water YES Central Heating NO?

Hi my Main combi boiler just wont fire up for the central heating. No errors on the boiler. I am using a digis... [Read more]
Mend boiler fire hot
1

how to fix my ravenheat csi85at boiler?

will not fire either dom hot water or central heating , spark firing , fan running no main fire
Mend pump 3 valve

Fitting New CH Pump and 3 Port Valve?

Hi, Further to my on going saga... I had elected to change the 3 port valve - as it had an intermitant f... [Read more]
Mend worcester water luke warm
1

Worcester 350 water luke warm?

Recently changed main PCB now water luke warm CH okay. Demand light does not indicate. Checked circuits as per... [Read more]
Mend water change pcb
1

Worcester 350 Hot water only warm?

Had reason to change main PCB but now luke warm water but CH ok. Do the PCB potentiometers need setting up for... [Read more]
Mend help help help
1

help help help?

Please someone help we have had about 4 heating techs out all safe gas registered and no one can help its cost... [Read more]
Mend main heater switch
1

main heater switch?

I have a dimplex xt24 series one and I require the main switch assembley that fits on the top of the heater. W... [Read more]
Mend switch central heating

how do i switch an to central heating ?

How do I use the central heating control box connected to the main boiler, which can switch the box from water... [Read more]
Mend greenstar hot water
1

greenstar 24i. No hot water?

No hot water delivery, the boiler kettles on the main heat exchanger with HW demand. Central heating demand n... [Read more]
Mend Heating, Home Heating Systems

Are ignition spares still available for Fireflame deluxe by Main?

The ignition system of late has been playing up. It still generates a weak spark that jumps the gap but not en... [Read more]
Mend question answer main
1

HE24 is dead?

I know this question has been asked this month but I can't see an answer. My ideal HE24 icos is dead with no L... [Read more]
Mend combi problem boiler fires
2

Main combi 30 HE fault?

Hi, I have a problem with my boiler, the boiler fires in and then cuts out. then the flame indicator start... [Read more]
Mend main burner works
1

boiler piolit lights but main burner do not?

pump,diverter and fan all works ok

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question