Recent: Replacing full bulb housing unit in Neff oven?

Mend Potterton

howtomendit.com find out how to mend just about anything.
Categories

Mend Running Pump Potterton

Free repair help

We have 57 questions about mending 'running pump potterton'

How to mend ... Running Pump Potterton

Pages 321
Mend Heating, Home Heating Systems

EP2002 programmer?

Hi, I recently replaced my old potterton controller for a new EP2002. I have recently noticed that when I just... [Read more]
Mend Heating, Home Heating Systems

Potterton powermax HE. Hot water but no heating?

I have a potterton HE boiler. I have no heating. The actuator is moving on the diverter valve and the pump is ... [Read more]
Mend Heating, Home Heating Systems

Potterton Profile 80E Starts OK on HW but not on CH?

Boiler would start (fan running for 20 seconds) but would not complete the ignition cycle. Replaced the PCB. A... [Read more]
Mend Heating, Home Heating Systems

potterton boiler?

why does potterton performa 24 boiler pump keep running on even when taps are turned off used only for hot wat... [Read more]
Mend Heating, Home Heating Systems

Intermittent problem on a Potterton Profile F?

I have had an intermittent problem on a Potterton Profile F for 2 days. The fan comes on, then the pilot ignit... [Read more]
Mend Heating, Home Heating Systems

potterton netaheat 10-16?

Boiler fires up ok bur front of case getting very hot and not shutting down boiler thermostat does not seem to... [Read more]
Mend Heating, Home Heating Systems

potterton performa 24?

power is on,pump running,no heating hot water, checked no power to fan and airflow sw. pcb ?
Mend Heating, Home Heating Systems

Main Burner problems - Potterton Profile 80e?

Main Burner starts up but for only about 3 to 5 mins then shuts off leaving pilot light on, main fan is runnin... [Read more]
Mend Heating, Home Heating Systems

how can i fix my potterton kingfisher MF CF40?

it continously trying to ignite with a tic-tak sounds but unfortunately no gas is coming out from the gas cont... [Read more]
Mend Heating, Home Heating Systems

Potterton 50E Neataheat profile - No Central Heating? ?

Potterton 50E Neataheat profile ( conventional heating system)... Hot water is working on demand.. ok C... [Read more]
Mend Heating, Home Heating Systems

Fault code E133 & E168 Flippin boiler!!?

Hi all I have the potterton pro max boiler too which decided to break down on me displaying fault code e133. ... [Read more]
Mend Heating, Home Heating Systems

how can i fix a potterton prima f?

IT seems to start the pcb clicks but nothing happens the pump is running but the boiler will not click on
Mend Heating, Home Heating Systems

Potterton Combi 80 cutting out on heating mode?

Heating fires for 1min - 2min then flames cuts off. Does'nt lock out and pump keeps running. The boiler contin... [Read more]
Mend Heating, Home Heating Systems

potterton will any body answer ?

10/16 works from cold heats to thermostat cuts out on thermostat.when hot. While rads still hot pump starts... [Read more]
Mend Heating, Home Heating Systems

Potterton Netaheat 10-16 MK11 No heating or hot water?

The pilot lights the fan is running, the pump is running, but the hot water and heating is not getting hot or ... [Read more]
Mend Heating, Home Heating Systems

potterton netaheater profile 60e?

System works fine for two days then goes mad i.e pump keeps running and boiler turns self on then over flows i... [Read more]
Mend Heating, Home Heating Systems

Potterton Kingfisher II no gas from vaulve?

Potterton Kingfisher II pilot light lit, water vaulves open and pump running, burner will not light, new therm... [Read more]
Pages 321

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question