Recent: Trayford close coupled toilet?

Mend Boulter Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Find out how to mend Boulter home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

How do I change burner nozzle?

My oil fired boiler keeps cutting in and out when cold. after about 10 minutes it runs ok. How do I get at the nozzle to change it? The boiler is a Boulter classic about 8 years old.,its burner is a Riello 40 type 443T58 which runs on 28 sec.Kerosene. The nozzle is covered in carbon and is inside a metal tube.

Mr.R.Foster
April 2008
Remove the metal flame tube - but mark its position first! The nozzle is then revealed and can be unscrewed, but avoid moving the electrodes as you do so. The nozzle will be covered in carbon, you aren't advised to dismantle them (but you can do). If no improvement, have the fuel pressure tested at the pump. Normally they run at between 125 and 150 psi. If you replace the nozzle, get the same one by looking at the number on it example .60 / 80 deg means the nozzle will pass .60 galls of fuel per hour, at a spray angle of 80 degrees. The other letter(s) on the nozzle refer to the actual spray pattern of the fuel spray itself.

John
April 2008

Automatic Answer

We may have found other answers which could help you.

Click here for Oil Fired Boiler

Mend Heating, Home Heating Systems
Find out how to mend Boulter home heating systems

Other models...

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Find out how to mend Boulter home heating systems