Recent: Trayford close coupled toilet?

Mend Sime Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Click here to mend Sime home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

Sime Friendly Format 80e, replaced diverter valve but rads. still get hot?

Boiler: Sime Friendly Format 80e
Problem: Radiators get hot when DHW is run.

I had assumed this was the diverter valve, so ordered a new assy. (part: 6102806) and fitted. But it hasn't really fixed the problem, though it does seem to be marginally better.

When someone has a shower (say, a 10 minute duration) the radiators still get hot. It's as though the diverter valve is only allowing the shower to use some of the heat, and the rest is going round the CH circuit.

Could it be that the new diverter valve I fitted was faulty? Or maybe there is some other part that is causing the fault?

Thanks, Mike

Mike G.
June 2008
there is still some type of issue with the diverter valve or its actuator allowing hit water to pass into the central heat on dhw demand, more than that I would need to be infront of the boiler

T
June 2008

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Replaced Rads Boiler

Mend Heating, Home Heating Systems
Click here to mend Sime home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Click here to mend Sime home heating systems