Error code E90 on Zanussi Jetsystem 1000 washing machine?
My machine keeps stopping and the error code E90 appears.
I have trouble restarting it, although it does eventually finish the cycle. Model number is FJS 1025W. Error code E90 is not shown in the manual, how do I fix the problem.
e90 error in communication between main pcb and user interface.take lid off and you will see a blue wiring loom with 5 wires that goes from the main control pcb on the side of the machine to the front control panel.these get loose connections which in turn give this fault code.re-crimp loom connectors so there is a tighter connection on the user interface pcb or replace loom with a new one.
ck
July 2008
E90- Fault in tank fill pump
-Hoses obstructed,
tank fill pump,
wiring