potterton 80 combi boiler not igniting?

The lock out light comes on whenever I turn on the hot tap, I reset and try again and same happens. I have tried it with the heating as well and same think happens. I have noticed that the pressure gauge is below 1 bar (red arrow) can you tell me where I can raise the pressure to 1 bar. Is it in boiler or one of taps below? I have read fault findings and think this may be the problem if not can you please help?

maureen
August 2008
A filling loop should be fitted to your system and should be positioned very near the boiler. It will usually comprise of a 'butterfly' tap connecting to a flexible pipe which connects via a non return valve to one of the boiler pipes. Once located ensure the boiler is switched off, open the butterfly valve and the system should start to pressurise. Once upto pressure close valve and retry boiler. If you cant locate filling loopor are unsure check with a couple of plumbers to find what they would charge to repressurise a system. They will then also be able to demonstrate what to do in future & if this does not cure the problem they are already on site to diagnose it.

Robin S
August 2008
Mend Heating, Home Heating Systems
Free repair help for Potterton home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Free repair help for Potterton home heating systems