Recent: Trayford close coupled toilet?

Mend Riello Oil Filled Radiators

Mend Heating, Oil Filled Radiators
Find out how to mend it for free.

Ask Question
Mend Heating, Oil Filled Radiators
Mend repair fix Riello oil filled radiators

Mend > Oil Filled Radiators

Mend Heating, Oil Filled Radiators

Riello burner needs reset to start?

Can the amount of time the Riello 40 F5 burner pumps the oil before ignition attempted be increased? We have an in ground oil tank which needs a while longer to get the oil to the pump. Because of this burner does not fire and the reset button needs to be pressed to start it. This only happens if air temp is not too cold and the burner is off for several hours. This way the oil has slowly gone done in the pipe.

david
March 2009
Fit a Non Return Valve in the Suction Line, with the Arrow on the Valve pointing towards the Burner, this way the oil should not fall back to the tank!

Boiler Repairman - Ipswich
April 2009

Automatic Answer

While you wait for answers, we may have found some information which could help you.

Click here for Burner Reset Start

Mend Heating, Oil Filled Radiators
Mend repair fix Riello oil filled radiators

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Oil Filled Radiators
Mend repair fix Riello oil filled radiators