Entry delay required please not enough time to get to my alarm panel? Also same with when part alarm is set not enough time to get down the stairs to unset
Jk
March 2024
Got no delay on entry
Mukesh
November 2020
Ensure alarm is in the unset condition : Enter in your 4 digit engineering code ( the factory setting for this is 1234 if you have not already changed it ) : Then enter 00 : Then enter 33 : Now enter your entry delay time as a two digit number ( eg 5sec = 05 & 25sec = 25 ) : Now press PROG and the process is complete
Milt
November 2010
I can answer this question...
how do i set a delay entry time on the veritas 8 alarm?