Baxi Solo 2 60 PF - PCB Fuse Blowing?

Anyone have any ideas why the PCB fuse is blowing on my Baxi Solo 2 60 PF? When the fuse does blow, the 'Boiler On' light remains lit but the boiler does nothing. Could it be a problem with my pump, is it PCB or some other component?

SmellyDave
July 2006
Pump proven to be faulty. On removing the pump from connection and replacing the fuse the boiler came to life (would not light due to no water flow). Replaced pump and system now running. Thanks for help.

NowNotSoSmellyDave
July 2006
prob pcb, check for burn marks these pcbs smell like fish when burning out. to check pump turn off sparks and pull off connector with 3 cabels on front of pcb, then switch on. if still blows pcb fault