Miele Diswasher?
 
                Hi i have a Miele  G 1270 SCVI and i am getting a FO1 fault. i ahve googled it and it seems that the causes and remedy could be the following: Cause:
 NTC temperature sensor R30 or its connection leads short-circuited. would you know how to acess the temperature sensor since i would like to change or test it thanks?  
Remedy:
 1. Check the temperature sensor and its leads for continuity. At 68°F (20°C), the temperature sensor resistance should be approximately 14.9kΩ (± 750Ω); at 77°F (25°C), approximately 12kΩ (± 600Ω) (guide figures only).
 
2. Check the plug connections. 
3. Replace the temperature sensor, if necessary.
would you know how to acess the temperature sensor since i would like to change or test it thanks
            
             matthew
            
 March 2013