Recent: Trayford close coupled toilet?

Mend Baxi Bermuda Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Find out how to mend Baxi Bermuda home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

Baxi Bermuda 552 Propane back boiler?

The pilot light goes out for no apparent reason.
I've replaced thermocouple, cleaned the pilot jet, adjusted the pilot flame but still after 1 day or so it goes out.
The only thing I can see is that the pilot light flame sometimes does not envelop the thermocouple. It seems like the pilot flame deflector is not deflecting the flame completely over the thermocouple. Any suggestions welcome

Rod Dolman
September 2007
try replacing pilot injector

Tony
April 2009
If the thermocouple is not heated sufficiently then the pilot flame can go out intermittently.
I also once had a faulty brand new thermocouple..... which flummoxed me for a while!

Also the flame can go out if the flue is blocked or insufficient oxygen is present. If the flue is blocked you will get a build up of CO - which is inert and can extinguish the flame....

Phil B
March 2009
Mend Heating, Home Heating Systems
Find out how to mend Baxi Bermuda home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Find out how to mend Baxi Bermuda home heating systems