the problem you have is internal engine problems.  briggs and stratton had some problems with heat treating of the camshaft lobes. after a period of time of running the lobes become swiped causing the valves to not open to a proper clearance, thus causing compression buildup causing the flywheel to turn one revolution and then stop abruptly.
                 denny edwards litchfield outdoor power
                