4 hours ago: BT Studio 4500 cordless telephone?

Mend Vaillant Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Click here to mend Vaillant home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

vaillant vuw 242e?

fan starts up but nothing else happens then goes to lockout,i have linked the pressure switch out but will not fire up,no spark at electrode as well

dave
November 2007
have tried all them still no joy,electrodes are not sparking, boiler goes through sequence then goes to lockout

dave
November 2007
I had the same problem British Gas came today and fixed it, there was a blockage in the tube

deb6789
November 2007
Most probably is the APS. Check that there is voltage from the board to the switch, check AP tubes are intact and venturi's are clear of obstruction whilst your there.

MrA
November 2007

Automatic Answer

We may have found other answers which could help you.

Click here for Starts Pressure Switch

Mend Heating, Home Heating Systems
Click here to mend Vaillant home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Click here to mend Vaillant home heating systems