Mend heating thermostat fault
1

How can I fix my Glowworm 70FF boiler?

Hi. My boiler does not always start running when the programmer and thermostat are both "ON". The programmer l... [Read more]
Mend error fan problem

Glowworm Micron 50FF, software error?

We have a Glowworm Micron 50FF installed. It was not working, apparently a fan problem. Engineer changed fan t... [Read more]
Mend pressure pcb fault

how can i fix o.o pressure glowworm 18sxi blr?

f9 fault showing on facia board. pressure reading 0.0 checked connection between main pcb and pressure switch... [Read more]
Mend boiler heating fault

Glowworm Ultimate 70ff won't cold start properly?

I have replaced the air pressure switch and the pcb and still I have a problem. When the boiler comes on from ... [Read more]
Mend boiler fault ignition

What is wrong with my Glowworm micron 50ff?

Had problems with boiler faiilng to start and going to reset. The pcb, thermister and air pressure switch was ... [Read more]
Mend boiler heating fault

Glow.worm Ultimate 120ff somtimes not firing up?

My Ultimate 120ff will sometimes not fire up. it hapens sometimes once a day sometimes it will run perfectly f... [Read more]
Mend failed hello boiler
3

Has the Fan Assembly truly failed?

Hello all I have a Glow Worm Ultimate 120FF boiler that serves the central heating in my home. The system ... [Read more]
Mend boiler pcb fault
1

How can I fix my Glow.worm 30sxi?

F13 flashes up on the display indicating a 'main PCB connection fault.' The service engineer fiddled with the ... [Read more]
Mend 80 boiler fires

Glow-worm intermitent firing?

i have a Glowworm Hideaway 80 BFF boiler which has developed a fault that it only fires intermitently.Is it th... [Read more]
Mend turning itself off
2

My Glowworm Ulti.120FF,is continuously turning itself on and off?

The boiler fires up and runs ok for about a minute,before it starts to switch off and then reignite,this happe... [Read more]
Mend condensing boiler heating pcb
1

glowworm 30 cxi?

my 2 year old glowworm 30cxi keeps going to f13 fault i have changed the main pcb and the display pcb and the ... [Read more]
Mend central heating boiler PCB
2

glow worm 50?

i have glowworm micron 50works ok when it calls for hot water but will not always fire up for central heating ... [Read more]
Mend boiler fault pcb
7

PCB?? Glow worm Micron 50FF?

We are having problems with our boiler! It keeps switching off. When it does come on it only stays on for se... [Read more]