Recent: Clutch Cable change?

Mend Worcester

howtomendit.com find out how to mend just about anything.
Categories

Mend System Worcester Bosch

Free repair help

We have 142 questions about mending 'system worcester bosch'

How to mend System Worcester Bosch

Pages 76543
Mend heating pressure changed
1

Home Heating system?

I have a Worchester 24cdi when I turn the heating on the pressure increases to 3 bar, I have changed the overf... [Read more]
Mend worcester water 28
2

Worcester Bosch 28cdi vents water?

My 28 CDI vents water through the over pressure valve. I have replaced the valve but it still keeps venting es... [Read more]
Mend worcester bosch radiators pressure
2

worcester bosch 240 combi RSF?

i keep having to bleed my radiators as the pressure keeps rising to maximum when then heating is on? There see... [Read more]
Mend pressure gauge 28i
1

Replacing Pressure Gauge on WB Greenstar 28i?

I've just had a repair and service done on my Woster bosch greenstar 28i and every thing is now working ok. A... [Read more]
Mend worcester bosch oil boiler

worcester bosch 26/32 oil boiler + solar?

I have fitted thermal solar system to my oil combi heatslave 26/32. I have used a combi valve that directs any... [Read more]
Mend boiler not firing up
1

Boiler not firing up?

Hi, I have a 28i with a drayton wireless thermostat system. The thermostat is working fine as I have checked ... [Read more]
Mend worcester rsf combi
1

worcester 24i rsf combi heating?

hi, when in demand mode my boiler fails to light. fan does not run or pump, but hot water system is fine and w... [Read more]
Mend system pressure bosch
1

How can i fix my boiler?

System Pressure in Worcester Bosch boiler reads 0. What is causing this?
Mend worcester combi burner boiler
4

Worcester Bosch Heatslave 25/32 Combi Oil?

Worcester Bosch Heatslave 25/32 Combi Riello Burner, First off we bought this boiler about a year ago and move... [Read more]
Mend bosch water pump
1

How do you refill a Worcester Bosch 240 heating system?

The refill water loop is switched on, the pump is working but no water is going into the system. Why?
Mend oil refilled checked
1

Worcester Bosch 20/25 lock out after oil ran out then refilled?

Fuel delivered. Checked fuel in pipe to filter. Still in lock out after attempting to reset for past 48 hours.... [Read more]
Mend Heating, Home Heating Systems
2

My greenstar 24ri is making clicking sounds and needs resetting each mornin?

My Greenstar has just been serviced as it needed resetting each morning the Worcester agent says my system nee... [Read more]
Mend oil tank worcester
1

Underground oil tank and Worcester Bosch Boiler intermittent cut-out Why?

We have recently installed an underground Balmoral Bunded oil tank and a Worcester Bosch Utility Condensing Oi... [Read more]
Mend bosch boiler system
1

Bosch Worcester 25si boiler pre 2003 model?

My system seems to have developed a fault in that despite all hot water taps being off the hot water demand li... [Read more]
Mend worcester bosch 240
1

worcester bosch 240 combi rsf?

should the pressure vessel car tyre type valve have water coming from it? can't pressurise system for more tha... [Read more]
Mend bosch hot water
4

Bosch Worcester Highflow 400 no heating no hot water?

We've had an ongoing deries of problems which Brit.Gas are struggling with... 31 Dec: no heating/hot water - ... [Read more]
Mend heatslave full oil
2

Over-pressure on Worcester Bosch Heatslave 15/19?

I'll give you the full story. 2001 Worcester Bosch Heatslave 15/19 oil combi boiler; the pressure gauge showed... [Read more]
Mend third exchanger heat combi
1

I am on my third heater exchanger?

I am on my 3rd heat exchanger (37cdi Combi) We had major loss of bar pressure on the 1st one just after insta... [Read more]
Mend system water zone
1

how do i reduce system pressure on greenstar 28ijunior?

I put in more water because it was it reached the red zone and I topped it up til it reached the black bar and... [Read more]
Mend central system pump
1

How can I fix my Worcester Bosch central heating system?

The circulation pump short circuited and blew the boiled supply fuse. I replaced the pump but now the pump ru... [Read more]
Pages 76543

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question