I keep getting alarm 6, but the machine has drained, the only cure i have found is to lay the machine on its side for a few second, this cures the fault for a while but it returns after a few days, now it only clears until the next drain cycle, any ideas
remove the left hand side panel ( as you look at it from the front ).there is a tank in there and they block up and go mouldy.replacing it is the only way to clear fault.its called an iwms (inlet water management system)
ck
September 2008