Recent: Mountfield empress drive belt?

Mend Heatline Home Heating Systems

Mend Heating, Home Heating Systems
Find out how to mend it for free.

Ask Question
Mend Heating, Home Heating Systems
Click here to mend Heatline home heating systems

Mend > Home Heating Systems

Mend Heating, Home Heating Systems

My Heatline viso 24 will not heat the DHW to a decent temp?

Could anyone tell me why the DHW on my boiler is not hot enough. The temp is set to max and the burners are lit and there are no fault lights on.

Simon Sheffield
March 2010
I have the same problem though in my case the red LED on the front panel is flashing. I need to replace the DHW sensor, when this sensor fails the boiler will carry on supplying hot water but restricts it to 64degs cent. only. It does this by using the flow sensor and CH sensor to regulate the temp. at the taps

charlyfarly
May 2010

Automatic Answer

We may have found other answers which could help you.

Click here for Temp Hot Set

Mend Heating, Home Heating Systems
Click here to mend Heatline home heating systems

How to mend ...

Find out how to mend just about anything howtomendit.com for free repair help, information and advice.
Mend Heating, Home Heating Systems
Click here to mend Heatline home heating systems