Recent: Rain water getting in my Ford Ka?

Mend Potterton

howtomendit.com find out how to mend just about anything.
Categories

Mend Boiler Faulty Potterton

Free repair help

We have 55 questions about mending 'boiler faulty potterton'

How to mend Boiler Faulty Potterton

Pages 321
Mend boiler fault ignition
3

potterton Performer 24 is faulty?

My potterton boiler will not fire up the red light comes on stating no flame, have replaced the Pcb card with ... [Read more]
Mend potterton lynx boiler pressure
1

What can the fault be with constant running on lynx 2 combi boiler?

I have a Potterton Lynx 2 combi boiler that has had its fair share of problems over the years.It now fires con... [Read more]
Mend boiler ignition sensor
2

Potterton Netaheat 10/16 Mk 2 - Erratic ignition, clicking igniter?

My Potterton Netaheat (it's a good age I know) has developed erratic ignition. It does light up, but often aft... [Read more]
Mend boiler heating gas valve
3

Why is my Potterton Netaheat 16/22 cutting out?

Hi - can you help? My Netaheat 16/22 Electronic is cutting out. It was installed in 1987, serviced every 5 yea... [Read more]
Mend boiler fan faulty
2

Potterton Profle 60e not lighting?

Potterton Profile 60e had developed faulty fan. Changed fan and boiler worked for around 2hours then totally ... [Read more]
Mend heating repair fault
2

How do I remove PCB board?

The 407677 pcb in my potterton profile 40 is faulty ( thanks to this site for finding answers to symptoms). I ... [Read more]
Mend boiler pcb flame
1

Potterton Suprima 50 cuts out soon after ignition of main flame?

I fixed the 'lock-out' problem last year by resoldering all the suspect joints on the PCB. After working OK f... [Read more]
Mend boiler natural gas ignition
2

How can I get my Potterton Netaheat 10/16 natural gas boiler to light?

My Potterton Netaheat 10/16 natural gas boiler is about 30 years old and has worked well and still is in good ... [Read more]
Mend hot water flow
1

hot water flow?

Dear all I have a potterton puma 80e combi boiler. The hot water from the sink tap and Bath taps runs very ... [Read more]
Mend boiler heating plumbing
1

potterton 50el - heating but no hot water (cont.) - bump?

Hi Hi-spec, Hi Ray, Thanks again for your advice.... but i still have this problem. I have been away for... [Read more]
Mend boiler fault pressure switch
6

Potterton Profile 60e - fan stops and starts - pilot won't light?

Hi, When I switch the boiler on the fan runs for a couple of seconds, then stops for a couple of seconds, t... [Read more]
Mend boiler central heating sludge
1

Potterton Profile 30E keeps tripping on Central Heating?

My Potterton Profile 30E keeps tripping off and requires the reset button to be pressed to restart. This typic... [Read more]
Mend performa boiler problem
4

Potterton Performa 24 combi boiler on off cycling problem?

My Potterton Performa 24 combi boiler ignites correctly but only stays on for a minute initially then switches... [Read more]
Mend boiler pcb faulty
1

Problems with a Potterton Netaheat 10-16 Boiler?

Even with the central heating turned off the radiators come on with the hot water. I assume this must be an el... [Read more]
Mend boiler heating system fault
2

Potterton Netaheat - pump is on when system is off?

I have a Potterton Netaheat boiler - (not sure of the model number). This morning, although the system was tu... [Read more]
Mend boiler faulty repair
1

How can I fix Potterton Profile 60E boiler?

Potterton (Baxi) Profile 60E. Air pressure switch never operates, though I can cause it to flip over by blow... [Read more]
Mend heating boiler fault
2

How can I fix my potterton netaheat electronic 10/16?

When I turn my heating on the Gas boiler fires up and I can hear the pump turn on but none of the radiators he... [Read more]
Mend potterton pilot pump
7

Help - Potterton Flamingo 50?

Heating system not working - water in rads - pump working when system switched on, but doesn't appear that the... [Read more]
Mend fan problem boiler
2

fan problem on potterton promax 24he?

i have a potterton promax 24he condensing boiler.the problem is with the fan.on starting the boiler the fan sh... [Read more]
Mend boiler fault heating
14

No pilot light potterton netaheat 10-16 boiler -?

Boiler was working fine until gas supply was cut off due to faulty meter , gas meter was fixed within 6 hours... [Read more]
Pages 321

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question