Pages 65432
Mend boiler heat exchanger pressure

Bosch 35 he leaking & low pressure?

Bosch greenstar 35he plus low pressure & leaking inside boiler have replaced prv & expansion tank as both whe... [Read more]
Mend heating radiators system pressure

ideal c30 independant boiler?

when hot water demanded and radiators off rads start getting hot. checked divertor valve actuator ok and pin m... [Read more]
Mend boiler heating pressure
3

Why is the pressure on my Ariston boiler rising to nearly 4 Bar?

Hi Can anyone please advise me on why my Ariston Eurcombi A/27 MFFI pressure is rising from just over 1 Bar... [Read more]
Mend boiler heat exchanger combi

eurocal boiler?

Hi, my 12 year old eurocal oil combi boiler has been troublesome for some time. 1. water pressure goes high ,... [Read more]
Mend boiler pressure leak
1

ferroli f 28 losing pressure?

hi, my boiler is losing water at an alarming rate...i've checked all under floor pipework, nothing, bone dry. ... [Read more]
Mend boiler heat exchanger dhw

Why has Heat Exchanger on IDEAL ISAR HE24 gone?

So... At the end of 2008 (early December, so about 4.5 years ago). We had central heating installed for the... [Read more]
Mend combi heat exchanger sensors
6

Ideal Combi Logic boiler "L3" fault. ?

Whenever the temperature knob is turned up higher than half way, the boiler shuts down, flashing L and 3. Have... [Read more]
Mend switch problem start
2

28i Junior Low Water Pressure Switch?

Hi, Have got a lockout problem with my Worcester 28i Junior. Does not like to start if it has not been run ... [Read more]
Mend boiler heating sensor

Ferroli Modena 102 luke warm hot water?

Any help have Modena 102 sometimes when 1st time calling CH the gas flame is very low if flame doesn't spread ... [Read more]
Mend combi boiler hopefully problem
2

Saunier Duval Combi Boiler Pressure Rises?

Hi Hopefully someone can answer this problem for me please? I have a Saunier Duval Thema Condens F30e Bo... [Read more]
Mend combi heat exchanger boiler

How can I fix my Potterton Perfoma combi 24 boiler?

My potterton Perfoma boiler done not give hott water when the inlet water pressure valve is fully open. But w... [Read more]
Mend boiler heating fault

Glowworm Ultimate 70ff won't cold start properly?

I have replaced the air pressure switch and the pcb and still I have a problem. When the boiler comes on from ... [Read more]
Mend Vaillant Fault Code Hot Water
1

Vaillant Ecomax boiler - Fault Code F22 - Please help?

Major probs with my ecomax boiler. Over 2 weeks ago, when in shower noticed problem whereby hot water would ru... [Read more]
Mend boiler heating heat exchanger

ferroli 80e keeps going over pressure?

ferroli 80e keeps going over pressure without boiler switched on checked fill loop for passing found ok just t... [Read more]
Mend heating pressure condensing
1

Random hot water?

I sometimes have to open another hot tap before the boiler kicks in,sometimes it's ok.My boiler ia a Baxi cond... [Read more]
Mend boiler pressure heating
3

Rising water pressure in Vaillant Turbomax 837E?

The water pressure in this boiler continues to rise reaching the RED zone in about 10 days. Water is drained o... [Read more]
Mend boiler pressure heat exchanger
1

my ravenheat csi 85t boiler, has an internal leak?

My ravenheat csi 85t boiler developed a leak from the condensing heat exchanger, at the pipe washer.This was v... [Read more]
Mend worcester 24 si ii
1

Worcester 24 si II?

Hi I have a Worcester 24si II. It's was installed 9 years ago. Had British gas around on monday for a new ins... [Read more]
Mend combi heat exchanger clogged

Could boiler heat exchanger be clogged?

My boiler seems to take ages to deliver hot water to the taps... over a minute, more to bathroom which is loca... [Read more]
Mend boiler pressure heat exchanger
1

Pressure problems with Vaillant Turbomax Plus 824?

The pressure reading on our Vaillant Turbomax Plus 824 is reading above 3 bar when the central heating is swit... [Read more]