Recent: Gaggenau fridge alarm problem?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Boiler Water Vessel Heating

Free repair help

We have 63 questions about mending 'boiler water vessel heating'

How to mend Boiler Water Vessel Heating

Pages 4321
Mend water starts years

vokera compact hot water ok,heating starts then locks out?

vokera compact 5 years old hot water working ok.when heating fires up boiler keeps going to lock out re set.ha... [Read more]
Mend ideal heating turn

boiler wont ignite,help need a wash?

ideal combi.when heating comes on it ignites,when pre-heat comes on it ignites.but when turn hot water taps on... [Read more]
Mend classic pressure boiler
2

ideal classic ff280 pressure problem,help?

when i top up the pessure to 1.0bar and dont use boiler the pressure will remain ther.go,s back to 1.0bar when... [Read more]
Mend boiler pressure problem 24
2

how can i fix a vokera boiler?

how do I fix a pressure problem on a Vokera Compact 24 Boiler? The pressure goes to 3 bar in the red & when I ... [Read more]
Mend boiler pressure hot water
2

how do i fix my worcester bosch 230 boiler?

my boiler currently has no pressure and is becoming a regular problem and so i have no hot water or heating, b... [Read more]
Mend pressure expansion problem
2

How can i put pressure in expansion vessel on vokera 20/80 rs flomatic?

I have a problem with pressure on my pressure gauge when my central heating is on the pressure goes to just co... [Read more]
Mend potterton performa pressure
1

potterton performa 28(condensing) combi?

why does my combi keep losing pressure?? i have no apparent leaks anywhere and i know there is about 0.75 bar ... [Read more]
Mend radiators system baxi
2

Just changed 2 rads and boiler fires up but then shuts down?

I have just changed 2 radiators and re pressurised the system to 1 bar - Baxi Bahama 100 Combi Bolier. When I ... [Read more]
Mend baxi expansion water
2

my baxi 105e instant combi expansion vessel water in it?

i have been having probs with the combi losing pressure and then going over 3bar when the central heating is o... [Read more]
Mend glow worm error
1

Glow worm 30ci - shutdown at 18C - 0.5 bar error code, and leak on top up?

The system ran at 20C degrees for a long time, with power down over night for about 7 hours on clock. Went a... [Read more]
Mend pressure each time boiler
1

Pressure rising each time boiler used?

Have Glow-worm Combi 30ci plus. Had the (cracked) expansion vessel replaced after leaking. Boiler pressure now... [Read more]
Mend low pressure problem
10

Low pressure warning light on Glow Worm Compact 100e?

Hello, I had a problem 2 years ago with my Glow worm Compact 100e, which would not switch from heating to hot ... [Read more]
Mend vaillant problem boiler
3

Vaillant VCW sine18 T3 WFH-hot water supply problem?

My boiler will not provide hot water at the tap unless it is running in heating mode when the tap is opened (p... [Read more]
Mend water pressure filling
1

How can I fix my Ferroli combi boiler losing water pressure?

I have a Ferroli Moderna combi boiler and have to keep on re-pressurising the system (by using a filling loop)... [Read more]
Mend loud burner boiler
4

LYNX 2 LOUD SQEAL LIKE THE PUMP BUT COMING FROM INSIDE WERE BURNER?

WHEN BOILER FIRES UP ON HOT WATER OR CENTRAL HEATING LOUD NOISE LIKE THE PUMP IS COMING TO A HAULT THEN FLAME ... [Read more]
Mend potterton puma combi
1

Hissing and banging?

Potterton Puma 100E combi wall hung, Heating works fine no problem, on hot water start up boiler hisses then b... [Read more]
Mend ferroli optima hot water
2

Ferroli Optima 901 -Intermittent Hot water problem?

Hi I have a Ferroli Optima 901 combi boiler and have recently been experiencing intermittent problems with no ... [Read more]
Mend help heating told
2

vaillant 242 eh combi/boiler leaking at the b t m.john?

please can anyone help me the heating engineer told me that my d. h. w.heat exchanger was leaking water also m... [Read more]
Mend baxi combi works
19

Fixing a Baxi 105e Combi which reports a fault when cold, works when reset?

Hi - this has baffled me and the heating engineer I've called in to look at it. My Baxi 105e has been reportin... [Read more]
Mend potterton puma heating
5

potterton puma 80e(pressure buildup)?

when central heating running the boiler pressure just keeps on rising until water is released from P.R.V. C.H.... [Read more]