Recent: Staiger RCL-07?

Free repair help and information

howtomendit.com find out how to mend just about anything.
Categories

Mend Central Heating Hot Water Pcb

Free repair help

We have 80 questions about mending 'central heating hot water pcb'

How to mend Central Heating Hot Water Pcb

Pages 4321
Mend boiler central heating PCB
1

Ravenheat CSI 85AT Boiler. Central Heating not working?

After switching the setting on my Ravenheat CSI 85AT Boiler to Central Heating and Hot Water (its been set to ... [Read more]
Mend combi central heating ravenheat
8

Ravenheat CSI 85T?

Hello, I've had a good look around this site and can't find an identical issue, so I'm hoping someone can h... [Read more]
Mend boiler pcb lockout
5

Potterton Suprima 50?

Hi, I have a Potterton Suprima 50 that was constantly locking out. The upgraded PCB sorted that problem but no... [Read more]
Mend baxi problem boiler works fine
5

Baxi Bahama 100 - Hot water problem?

Hi there to anyone who can possibly help me with the above problem. The boiler works fine for central heati... [Read more]
Mend combi boiler pcb no hot water
3

Baxi 80E No hot water, CH ok. !!?

Got a Baxi 80 E Combi, Central Heating is perfect but NO hot water. The Hot Water neon does not illuminate wha... [Read more]
Mend saunier duval thelia 23
8

saunier duval thelia 23?

new house - dead boiler. I have replaced the diverter valve & piece which it mounts to, now the micro switches... [Read more]
Mend central heating boiler PCB
2

glow worm 50?

i have glowworm micron 50works ok when it calls for hot water but will not always fire up for central heating ... [Read more]
Mend boiler fault hot water
2

Vokera Linear 24 timer fault?

The boiler works fine in both hot water and central heating modes until the timer is set. When the time is rea... [Read more]
Mend central heating burner pcb
3

Glowworm Ultimate 40FF - main burner keeps going out and relighting?

The pilot lights, its continues to spark then the main burner lights then the main burner goes out after a few... [Read more]
Mend Worcester Central Heating PCB
3

24i rsf worcester - not working sometimes?

sometimes i need to push the front of PCB to get it started otherwise it will not start (both hot water and ce... [Read more]
Mend boiler combi pcb
2

ravenheat combi boiler(rsf84et)?

hello can any body help me ? has any body had simillar problems with ravenheat combi boiler RSF 84 ET ? NO H... [Read more]
Mend boiler central heating pcb
1

Can anyone diagnose the problem with my Ferroli Optima 901?

I have a Ferroli Optima 901. When the hot water is run for a period of 3-4 minutes the boiler cuts out and the... [Read more]
Mend boiler pcb water damage
2

My Glowworm 50FF Boiler Won't turn off?

I'm having a problem where my glowworm 50FF boiler won't turn off. Have just had a new pcb fitted due to water... [Read more]
Mend classic ff heating boiler
1

Ideal Classic FF 260 central heating boiler?

The boiler strikes normally but after 5-6 minutes switches off, in just central heating and just hot water mod... [Read more]
Mend boiler central heating sludge
1

Potterton Profile 30E keeps tripping on Central Heating?

My Potterton Profile 30E keeps tripping off and requires the reset button to be pressed to restart. This typic... [Read more]
Mend boiler heating pcb
10

Baxi Solo 50/4 Wall Mounted PF Burner Shutdown Problem?

My Baxi Solo 50/4 Wall Mounted PF gas fired central heating boiler ignites when the thermostat calls for heat,... [Read more]
Mend boiler pcb faulty
1

Problems with a Potterton Netaheat 10-16 Boiler?

Even with the central heating turned off the radiators come on with the hot water. I assume this must be an el... [Read more]
Mend central heating thermostat PCB
1

Euro combi - Red light keeps coming on and cutting off boiler?

I have a Euro combi boiler and the red light keeps coming on and cutting off when in central heating mode and ... [Read more]
Mend boiler central heating combi boiler
1

how can I fix my central heating boiler?

I have a Ferolli 77CF combi bolier 1993. If we turn on the hot water we have to continually hold down the pilo... [Read more]
Mend boiler PCB central heating
1

Potterton Puma 80 c/h intermittently working until warmed up?

My boiler, Potterton Puma 80 (may be an 80e as no pilot light?) has been working fine for 5 years and now it t... [Read more]
Pages 4321

Ask Question

Ask your question Do you need free help? Ask your question.

howtomendit.com for free repair help, information and advice.
Ask Question