Pages 65432
Mend boiler pressure faults
4

Expansion Vessel Help needed ! ?

How do you test an Expansion Vessel for faults - should there be air in there when you press the bleed nipple ... [Read more]
Mend pressure heating expansion vessel

High Pressure on a Saunier Duval SD 620?

the boiler is filled to the required 1Bar when cold and recently has been exceeding the 2 Bar pressure when th... [Read more]
Mend glow worm help

Glow Worm 30ci - got hot water but no C.heating?

Firstly just like to say thanks to all that help on here. I am fairly competent with this kind of stuff, and ... [Read more]
Mend boiler pressure expansion vessel
3

How to pressurise expansion vessel?

Vaillant Combi boiler VCW 282 central heating expansion vessel needs to be re pressurised as it is causing hig... [Read more]
Mend boiler pressure heating
1

PRESSURE DROPPING?

After switching heating off to go to bed every morning bar pressure has dropped to zero i have to top up to 2 ... [Read more]
Mend worcester boiler water tank
2

Worcester Danesmoor oil boiler venting hot water to expansion tank?

I have a Worcester Danesmoor Utility 26/32 oil fired boiler on a vented CH/HW system. When the boiler is runni... [Read more]
Mend boiler pressure expansion tank
2

Glowworm 330+ Central Heating boiler question?

1. What should the water expansion tank pressure be? 2. The Red guide hand is on 2bar but the pressure (col... [Read more]
Mend central heating boiler water pressure

Sime Friendly Boiler issue - radiators hot, sometimes not?

This is a bizarre one (or maybe it's more common than I think!). Here goes:- Due to falling water pressure ... [Read more]
Mend central heating boiler system failure

The boiler will not fire up in 'Central Heating Mode'?

A new expansion valve has been fitted but the heating was not working before this
Mend central heating combi boiler expansion vessel

Vaillant VCWGB242EH GC 4704413 Combi goes out immedi?

Hi, am working on the above boiler, was leaking at the auto air vent so tested the expansion vessel to find it... [Read more]
Mend central heating boiler noise

Apollo Fanfare Boiler Problem?

My Apollo Fanfare seems to work ok. Apart from a quite loud bang when the central heating is on....it does no... [Read more]
Mend central heating boiler expansion tank
6

Why does my Bosch Worcester 24 CDi keep repressurising itself?

My bolier keeps repressurising itself slowly through use. I can't use my central heating as the PRV has broke ... [Read more]
Mend combi boiler central heating pressure

How can I sort out pressure on my Worcester combi boiler?

The pressure gauge on my Worcester Bosch Combi boiler suddenly shot up to maximum and water was running from t... [Read more]
Mend boiler pressure leaks

how to fix baxi 133 he?

hi there i have a baxi 133he combi it all works fine apart from the pressure gauge sits at zero .then when the... [Read more]
Mend boiler pressure heating
3

Vokera linea 24 pressure problem?

I have a problem with my Vokera boiler, when cold the pressure will drop to almost zero, if I top up the press... [Read more]
Mend heating radiators pressure
5

Pressure dropping on worcester 241 RSF boiler?

Hi i hope someone can help me, the pressure has been dropping on our boiler and has noe gotten to the point wh... [Read more]
Mend boiler pressure expansion vessel
4

Vaillant VCW GB242 high pressure ?

I have a VAILLANT - VCW GB 242 EH boiler installed by the previous previous owner and no manual. When the hea... [Read more]
Mend central heating boiler thermostat

my sime boiler is heating water ok but the central heating part wont start?

the central heating part of boiler wont fire up. the room thermostat appears ok.theres a expansion tank on rea... [Read more]
Mend boiler heating safety valve

boiler?

hi i hav vokera linea 24. i set my boiler at 1/1.5 bar and is ok then when the heating kicks in th pressure g... [Read more]
Mend heating expansion boiler
2

When is it time to change a boiler?

I have 59 years old boiler for radiant heating. It's working. I just change the expansion tank due to leak. Do... [Read more]