How to mend Heating Hot Water Valve

Mend boiler heating fault
1

ferroli optimax 25c?

no hot water turn on tap 3 way valve gos to heating and pump stops boiler gos off 03 fault .put 3 way valve to... [Read more]
Mend boiler pressure heating radiators
1

How can i fix my ariston micro genus 23?

Hi,My pressure reading when off is almost zero(first line in red)boiler will turn on and run fine but then the... [Read more]
Mend hot into loft tank
1

I have hot water overflowing into the loft expansion tank?

I had a new cylinder fitted in December 2009 and the plumber also upgraded the 3way valve to an electric one. ... [Read more]
Mend water hot valve system

How do I fix water hammer just started on closure of hot water valve?

My central heating system (vented, not sealed - boiler replaced about 4 years ago) has suddenly developed a lo... [Read more]
Mend hot water combi
1

No Hot water from combi?

I have a 10 year old Vokera Linea 28. I have no hot or cold water coming through the taps at all. The central ... [Read more]
Mend potterton problem hot water radiators

Potterton Performa 28 problem?

Our Potterton Performa 28 is playing up - when running the hot water the radiators are warming up even though ... [Read more]
Mend hot water heating
1

hot water but no heating?

hello. i have a worcester danesmoor oil boiler, its a sealed system, honeywell st699b programer honeywell V... [Read more]
Mend 105e hot water

Any more suggestions for my baxi 105e please?

woke up the other morning with no heating or hot water from my 5 or 6 year old baxi 105e combi.i have,within t... [Read more]
Mend problem replaced tested

problem with ravenheat rsf 820/20?

just replaced divertor valve, tested water and heating and was working fine, just put all the covers back on, ... [Read more]
Mend vokera excel water
1

Vokera Excel 80SP Service Kit T0019?

We have recently been having problems with our hot water where it only seems to get hot whilst the central hea... [Read more]
Mend potterton pilot heating
1

Potterton Profile (50e?) boiler pilot light on but no hot water or heating?

I've had a search for this issue and I have seen similar but most say they have issues with the pilot light no... [Read more]
Mend low water turbomax
1

low water pressure F28 lockout, Vaillant Turbomax plus 828E ?

Hi guys, Hope you can help. I've viewed all the relevant and some of the irrelevant posts on similar subjects ... [Read more]
Mend baxi combi 105e boiler heating hot water
3

baxi combi 105e boiler,no heating or hot water?

woke up the other morning with no heating or hot water from my 5 or 6 year old baxi 105e combi.i have,within t... [Read more]
Mend ariston mffi heating

Ariston microcombi 23 MFFI?

Have a problem with heating. 2 rad's upstairs hot and working OK, but down stairs no heat rad's remain cold,I ... [Read more]
Mend glow worm pressure
1

Glow worm Compact Electronic Boiler?

My boiler is leaking water and it's got quite bad recently. The pressure is just above 2 and the red marker i... [Read more]
Mend 30 heating working

ferroli domi 30 heating not working?

change gas valve hot water working heating cuts off when new valve fitted both worked rang ferroli 3 times eve... [Read more]
Mend vaillant turbo max
2

vaillant turbo max?

only have hot water when heating is on , have changed diaphragm, still same , if boiler on hot water only, and... [Read more]
Mend problem diverter valve boiler
4

Problem with the diverter valve - vaillant turbo max boiler?

My boiler is 13 years old but in good condition so I don't want to replace it. We've replaced the diverter va... [Read more]
Mend boiler heating fault
1

EVO HE c22/24 Condensing boiler?

Boiler evo c22/24 HE, hot water inconsistent. Sometimes hot and sometimes just warm. Presently set on full hot... [Read more]
Mend heating hot pump
6

Why can we only get heating when hot water on also now(Dual programer)?

We recently needed to replace head valve due to pump over run problem.(Boiler is Potterton Profile) On putting... [Read more]

Ask Question